  Datasheet File OCR Text:
  european foundation for quality management ?eneral member of certified management systems new compact power entry module ef11 consisting of appliance inlet and circuit breaker for equipment. now for high currents up to 16 a iec/en 20 a ul/csa appliance inlet with circuit breaker new version with line filter available beginning of 2002 e f 1 1 e f 1 1 e f 1 1 e f 1 1 e f 1 1 e f 1 1
www.schurter.com power ent r y module / ger?testecker-kombielement ef11 power entry module for high current type ef11 ?panel mount: ?screw-on version, front or rear-side ?snap-in version, front-side ?appliance inlet with circuit breaker type ta 45 characteristics circuit breaker 2-pole, rocker actuated, non-illuminated or illuminated combined with thermal overload protection optional with undervoltage release or remote trip release all single elements wired unwired versions available on request qualified for use in equipment according to iec/en 60950 technical data rated voltage 125/250 vac rated current i n 10 up to 16 a; vde 10 up to 20 a; ul, csa, see table 1 dielectric strength > 1,5 kv between l-n (50 hz, 1 min.) > 3 kv between l/n-pe allowable ambient air temperatures t a ?0 ? to +55 ? degree of protection (front side) ip40 acc. to iec 60529 protection class suitable for equipment with prot. cl. i, acc. to iec 61140 terminals quick-connect 6,3 x 0,8 mm panel thickness s screw-on: s = max. 8 mm snap-in: s = 1,5/2/2,5 mm materials: housing thermoplastic, black, ul94 v-0 appliance-inlet acc. to iec/en 60320-1/c20, protection class i, pin-temperature 70 ? (cold condition) circuit breaker acc. to iec/en 60934, ul 1077, type ta 45 csa 22.2 no 235 2-pole rocker switch, illuminated or non-illuminated optional with undervoltage- or remote trip release short circuit capacity icn: at i n < 3 a/240 vac: 10 x i n at i n 3 a/240 vac: 300 a c us
www.schurter.com power ent r y module / ger?testecker-kombielement ef11 t echnical data (continued) ci r cuit b r eaker t ripping characteristics i n < 3 a t ripping characteristics i n 3?< 18 a t ripping characteristics i n 18 a t ype / t y p t a45 rated current nennst r om i n <3 a 1 pole protected 1polig gesch?tzt 2 pole protected 2polig gesch?tzt ambient temp. umgebungstemp. +23 c 10'000 60 2`000 1`000 500 200 100 50 20 10 5 2 1 0,5 0,3 0,2 0,1 [ sec ] [ min ] 10 5 1 30 20 1,05 multiple of rated current [ x i n ] 10854321,32 t ripping time / ausl?sezeit t ype / t y p t a45 rated current nennst r om 3 a i n <18 a 1 pole protected 1polig gesch?tzt 2 pole protected 2polig gesch?tzt ambient temp. umgebungstemp. +23 c 10'000 60 2`000 1`000 500 200 100 50 20 10 5 2 1 0,5 0,3 0,2 0,1 [ sec ] [ min ] 10 5 1 30 20 1,05 multiple of rated current [ x i n ] 10854321,32 t ripping time / ausl?sezeit t ype / t y p t a45 rated current nennst r om i n 18 a 1 pole protected 1polig gesch?tzt 2 pole protected 2polig gesch?tzt ambient temp. umgebungstemp. +23 c t ripping time / ausl?sezeit 10'000 60 2`000 1`000 500 200 100 50 20 10 5 2 1 0,5 0,3 0,2 0,1 [ sec ] [ min ] 10 5 1 30 20 1,05 multiple of rated current [ x i n ] 10854321,32 effect of ambient temperature the unit is calibrated for an ambient tempe- rature of +23 ?. to determine the rated current for a lower or higher ambient tempe- rature, use a correction factor from the table on the right side: example rated cur r ent at +23 ? / nennst r om bei +23 ? 6,0 a ambient temperatu r e / umgebungstemperatur +40 ? cor r ection factor / kor r ekturfaktor 1,08 chosen rated current at +40 ? ambient temperatu r e 6 a x 1,08 = 6,5 a * temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. ?0 0,89 ? 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16 * ambient temperatu r e [?] / cor r ection * umgebungs- factor / sc r ew-on mounting / schraubmontage dimensions panel cut-out / mounting sc r ew to r que 0,5 nm see table 1 r 2.6 78.7 - 0.15 + 0.05 11.95 0.08 31.7 -0.08 +0.05 ca. 72 40.55 2.3 0.05 4.8 26.55 0.8 41.7 10.6 76.7** 32.2 - 0.10 +0.05 2.8 12.2 0.08 79.2 - 0.15 +0.05 r 6 3.3 0.05 5 90 - 0.15 +0.05 6.4 36 r4 . 7 10.4 100 r 2.95 0 . 05 r 2.9 5 0.05 32.5 0.10 79.5 0.10 5.25 0.05 90 0.10 3.6
www.schurter.com power ent r y module / ger?testecker-kombielement ef11 dimensions snap-in mounting / schnappmontage panel cut-out o r der code for ef11 (o r der example) type / o r der code t a45 (2-pole rocker-switch without accessories) f1 . a b t w f 1 5 0 c 0 . } see table 1 00 10. 01 wiring 1 = wi r ed p r otection class 0 = class i, housing black panel mount 0 = sc r ew-on version 2 = snap-in version , s = 1,5 mm 3 = snap-in version , s = 2,0 mm 4 = snap-in version , s = 2,5 mm t erminals 1 = quick connect terminals steckanschl ? sse 6,3 x 0,8 mm 00 = without line-filter please note that schurter will establish an internal new part number for logistical use in addition to the order code. for example, order code f1abtwf200c0001 will refelct the internal part number of ef11.0035.0010.01 other versions on r equest unwi r ed versions diagram 78.7 -0.15 +0.05 11.95  0.08 31.7 - 0.08 + 0.05 2.15 r 2.6 ca. 72 40.55 s  0,05 2.3  0.05 4.8 26.55 41.7 10.6 76.7** 36 83 - 0.15 +0.05 r4 . 7 32.2 -0.10 +0.05 r 2.8 12.2  0.08 79.2 - 0.15 +0.05 1.9 r 2.95  0.05 r 2.9 5  0.05 32.5 - 0.10 + 0.05 79.5 - 0.15 +0.05 ** v ersion t a45 with undervoltage r elease ta45
power ent r y module / ger?testecker-kombielement ef11 t able 1 selection for type t a45 o r der example abt w f 150 c0 line-switch 2-pole, r ocker actuated quick connect terminal other types on r e quest without illumination / with illumination / 220 240 v mit beleuchtung 110 120 v 3 5 p1 a diagram abc abt abd a02 a12 a32 a04 a14 a34 p2 p1 6 3 4 3 p2 p1 p2 p1 6 5 colours / farben switch f r ont / rocker w black / schwarz white / weiss b black / schwarz black / schwarz 6 black / schwarz orange transp. f embossed h printed / bedruckt white k printed / bedruckt black l printed / bedruckt white surface / illustration / colour of print rocker legend / wippenbeschriftung l o on off on off l o m printed / bedruckt black p printed / bedruckt white r printed / bedruckt black surface / illustration / colour of print ?without thermal overload protection: code c00 ?with thermal overload protection: rated current i n (a) i n code 10,0 100 11,0 110 12,0 120 i n code 13,0 130 14,0 140 15,0 150 i n code 16,0 160 17,0 170 18,0 180 i n code 19,0 190 20,0 200 www.schurter.com without r elease: code c0 undervoltage r elease remote trip r elease p2 p1 u< p2 p1 b u< p2 p1 b a u< p2 p1 c u e z a code rated voltage u n 2 3 4 240 v ac 230 v ac 120 v ac } } i n = 16 a l o o o i i position of the rocker legend e.g f


▲Up To Search▲   

 